Interoute shares measures taken to win energy efficiency award

18 May 18

​There were celebrations at Interoute recently as the pan-European cloud and network company was lauded for its efforts in energy saving.

Interoute has 15 data centres connected to 126 cities but received the SIG GIGA Trophy in recognition of its efforts to increase energy efficiency and reduce the carbon dioxide consumption of its data centre in Geneva, Switzerland.

The award is issued to companies in Switzerland that demonstrate long-term commitment to improving energy-efficiency and those that have reduced electricity consumption more than one gigawatt hour per year.

Interoute network services engineering VP Phil Martin says the company is delighted to be recognised for its efforts in data centre energy efficiency with the SIG GIGA Trophy.

“The amount of energy we now save annually is enough to power a small Swiss village for a year,” says Martin

“Becoming more energy efficient not only benefits the environment, it also helps us manage costs and make our services more competitive saving hundreds of thousands of Euros each year.”

Some of the measures put into place by Interoute to improve its data centre energy efficiency include a variety of cooling and power implementations, like:

A custom-made cold aisle containment system

Around a thousand racks in the Geneva data centre have been fitted with tailored cold aisle containment doors and panels, which means that only the racks are cooled rather than the whole room. This reduces overall energy expenditure by ensuring consistent and predictable airflow to eliminate server hotspots, as well as being able to set specific temperatures create the most efficient operating environment.

Underfloor cooling pathways

Interoute built sealed pathways underneath the raised floor to enable cold air to be sent directly to the containment systems. According to the company, the result has approximately halved the amount of underfloor space that required cooling, providing substantial energy savings given the 2,200 square metre data centre footprint. The pathways are also used for technical requirements like cable trays for fibre and copper wiring and space for fibre detection systems.

New cooling systems

The existing 58 cooling units that used a fixed fan speed have recently been upgraded to accommodate variable fan speeds to enable speeds to be accurately matched to demand and consequently avoid excess power usage. The data centre has also been fitted out with a new 1.2MW free cooling infrastructure which on cold days brings in air from the outside and reduce the need for powered cooling units.

New static uninterruptible power supply (UPS) systems

Half of the existing rotary UPS systems were recently replaced with new static versions which are more energy efficient.

Rebalancing

Where possible, Interoute has consolidated servers and concentrated loads into fewer racks to effectively shut down cooling and other equipment in empty areas.

MulteFire announces industrial IoT network specification
The specification aims to deliver robust wireless network capabilities for Industrial IoT and enterprises.
Google Cloud, Palo Alto Networks extend partnership
Google Cloud and Palo Alto Networks have extended their partnership to include more security features and customer support for all major public clouds.
DigiCert conquers Google's distrust of Symantec certs
“This could have been an extremely disruptive event to online commerce," comments DigiCert CEO John Merrill. 
Schneider Electric's bets for the 2019 data centre industry
From IT and telco merging to the renaissance of liquid cooling, here are the company's top predictions for the year ahead.
China to usurp Europe in becoming AI research world leader
A new study has found China is outpacing Europe and the US in terms of AI research output and growth.
Google says ‘circular economy’ needed for data centres
Google's Sustainability Officer believes major changes are critical in data centres to emulate the cyclical life of nature.
52mil users affected by Google+’s second data breach
Google+ APIs will be shut down within the next 90 days, and the consumer platform will be disabled in April 2019 instead of August 2019 as originally planned.
Ramping up security with next-gen firewalls
The classic firewall lacked the ability to distinguish between different kinds of web traffic.